[صفحه اصلي ]     [ English ]
مجله چشم پزشكي ايران awt-yekta Iranian Journal of Ophthalmology
:: جلد 20, شماره 4 - ( مجله چشم پزشکی ایران 1386 ) ::
برگشت به فهرست نشريات جلد 20 شماره 4 صفحات 20-23
XML The Accuracy of Ocular Sonography in Detection and Measurement of Intraocular Foreign Bodies Print

[English Abstract]
نويسندگان: دكتر محسن فروردين ، دكتر مرسل مهريار ، دكتر محمد کران جم ، دكتر حسين اشرف ، دكتر مرتضی مهديزاده ، دكتر منصور رحيمی ، دكتر حميد حسينی ، دكتر سيروس سيوفی * و دكتر مهناز مصلائی
* - siyoofisirus@yahoo.com
نوع مطالعه: پژوهشی | موضوع مقاله: عمومى
چکيده مقاله:

Purpose : To evaluate the accuracy of ocular sonography in measurement of size of intraocular foreign bodies (IOFB)

Methods : In a case series study, 58 consecutive patients with intraocular foreign body were included. Ocular sonography was performed to detect intraocular foreign body and the results were compared with the same intraoperative findings.

Results : Metallic material was found to be the most prevalent one (71%) followed by glasses (12%), stone (8%) and wood (6%). Ultrasound localized the foreign body lodged in the lens in 10.3%, in the angle in 3.4% and in the vitreous or vitreoretinal region in the rest of them (86.3%). The mean size measured by ocular sonography was 3.5×4.5 mm and that was reported by the surgeon was 2.9×4 mm. While the reports of sonography in detection and localization of IOFB was completely comparable with surgical findings, size measurements were considerably different from true measurements after intraocular surgery.

Conclusion : Ocular sonography showed mostly overestimation in measuring intraocular foreign bodies. Although ocular sonography was one of the best methods for assessment of IOFB, it doesn't have high accuracy in estimation of size of IOFB.

 

Iranian Journal of Ophthalmology 200820(4):20-23
واژه‌هاي كليدي
متن كامل [PDF 49 kb]
نحوه استناد به مقاله
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
Farvardin Mohsen, Mehryar Morsal, Karanjam Mohammad-A, Ashraf Hossein, Mehdizadeh Morteza, Rahimi Mansoor et al. et al. et al. The Accuracy of Ocular Sonography in Detection and Measurement of Intraocular Foreign Bodies Iranian Journal of Ophthalmology, 2008; 20 (4) :20-23
URL http://www.irjo.org/browse.php?a_code=A-10-11-60&slc_lang=fa&sid=1
فروردين محسن، مهريار مرسل، کران جم محمد، اشرف حسين، مهديزاده مرتضی، رحيمی منصور، و همکاران. The Accuracy of Ocular Sonography in Detection and Measurement of Intraocular Foreign Bodies مجله چشم پزشكي ايران، 1386; 20 (4) :20-23
ارسال پيام به نويسنده مسئول

ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

كد امنيتي را در كادر بنويسيد >
 
برگشت به فهرست نشريات جلد 20, شماره 4 - ( مجله چشم پزشکی ایران 1386 )
مجله چشم پزشكي ايران Iranian Journal of Ophthalmology
Static site map - Persian site map - English site map - Created in 0.078 seconds with 595 queries by AWT YEKTAWEB 2.0.6.5