[صفحه اصلي ]     [ English ]
مجله چشم پزشكي ايران awt-yekta Iranian Journal of Ophthalmology
:: جلد 19, شماره 4 - ( مجله چشم پزشکي ايران 1385 ) ::
برگشت به فهرست نشريات جلد 19 شماره 4 صفحات 21-27
XML Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients Print

[English Abstract]
نويسندگان: دكتر حيدر امينی *، دكتر عليرضا خدابنده ، دكتر ساسان مقيمی ، دكتر يداله اسلامی ، دكتر رضا زارعی و دكتر قاسم فخرايی
* - heydar_amini@yahoo.com
نوع مطالعه: پژوهشی | موضوع مقاله: عمومى
چکيده مقاله:

Purpose: To quantify the intraobserver reproducibility of retinal nerve fiber layer (RNFL) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients.

Methods: Twenty-six eyes of 26 glaucoma suspect patients were included. Complete ophthalmologic examination and standard automated perimetry were performed for all of them. RNFL measurements were done using GDx-VCC (Laser Diagnostic Technologies, San Diego , CA ) by an experienced operator. The test repeated immediately by the same operator.

Results: Patients were 24 to 70 years old (55.9±11.5 years). Twenty patients were female and 6 patients were male. Eighteen patients were ocular hypertensive and 8 patients had large cup to disk ratios. None of them had glaucomatous field defect in standard perimetry. The mean coefficient of variation for measurements of TSNIT average (Avg), superior Avg, inferior Avg, TSNIT-SD and nerve fiber indicator (NFI) were 0.77, 0.95, 0.91, 0.81, and 0.98 respectively. The mean coefficient of variation of GDx-VCC was 88.4 for the 5 main parameters (TSNIT Avg, superior Avg, inferior Avg, TSNIT-SD, and NFI).

Conclusion: GDx-VCC showed a good test-retest correlation and acceptable intraobserver reproducibility. NFI may be the most reproducible major GDx-VCC parameter in glaucoma suspect patients.

 

Iranian Journal of Ophthalmology 200719(4):21-27
واژه‌هاي كليديscanning laser polarimetry، reproducibility، GDx-VCC، glaucoma suspect،
متن كامل [PDF 63 kb]
نحوه استناد به مقاله
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
Amini Heidar, KhodaBande AliReza, Moghimi Sasan, Eslami Yadollah, Zarei Reza, Fakhraie Ghasem, Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients Iranian Journal of Ophthalmology, 2007; 19 (4) :21-27
URL http://www.irjo.org/browse.php?a_code=A-10-11-27&slc_lang=fa&sid=1
امينی حيدر، خدابنده عليرضا، مقيمی ساسان، اسلامی يداله، زارعی رضا، فخرايی قاسم، Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients مجله چشم پزشكي ايران، 1385; 19 (4) :21-27
ارسال پيام به نويسنده مسئول

ارسال نظر درباره این مقاله
نام کاربری یا پست الکترونیک شما:

كد امنيتي را در كادر بنويسيد >
 
برگشت به فهرست نشريات جلد 19, شماره 4 - ( مجله چشم پزشکي ايران 1385 )
مجله چشم پزشكي ايران Iranian Journal of Ophthalmology
Static site map - Persian site map - English site map - Created in 0.081 seconds with 592 queries by AWT YEKTAWEB 2.0.6.5