[Home ]     [ فارسي ]
Iranian Journal of Ophthalmology awt-yekta مجله چشم پزشكي ايران
:: Volume 19, Number 4 (Iranian Journal of Ophthalmology 2007) ::
Back to browse issues page 2007, 19(4): 21-27
XML Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients Print

Persian Abstract
Author(s): Dr. Heidar Amini *, Dr. AliReza KhodaBande, Dr. Sasan Moghimi, Dr. Yadollah Eslami, Dr. Reza Zarei and Dr. Ghasem Fakhraie
heydar_amini@yahoo.com
Study Type: Original | Subject: General
Article abstract:

Purpose: To quantify the intraobserver reproducibility of retinal nerve fiber layer (RNFL) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients.

Methods: Twenty-six eyes of 26 glaucoma suspect patients were included. Complete ophthalmologic examination and standard automated perimetry were performed for all of them. RNFL measurements were done using GDx-VCC (Laser Diagnostic Technologies, San Diego , CA ) by an experienced operator. The test repeated immediately by the same operator.

Results: Patients were 24 to 70 years old (55.9±11.5 years). Twenty patients were female and 6 patients were male. Eighteen patients were ocular hypertensive and 8 patients had large cup to disk ratios. None of them had glaucomatous field defect in standard perimetry. The mean coefficient of variation for measurements of TSNIT average (Avg), superior Avg, inferior Avg, TSNIT-SD and nerve fiber indicator (NFI) were 0.77, 0.95, 0.91, 0.81, and 0.98 respectively. The mean coefficient of variation of GDx-VCC was 88.4 for the 5 main parameters (TSNIT Avg, superior Avg, inferior Avg, TSNIT-SD, and NFI).

Conclusion: GDx-VCC showed a good test-retest correlation and acceptable intraobserver reproducibility. NFI may be the most reproducible major GDx-VCC parameter in glaucoma suspect patients.

 

Iranian Journal of Ophthalmology 200719(4):21-27
Keywordsscanning laser polarimetry, reproducibility, GDx-VCC, glaucoma suspect,
Full text [PDF 63 kb]
How to cite this article
Download citation data for: BibTeX | EndNote | Medlars | ProCite | Reference Manager | RefWorks |  
Send citation data to: CiteULike | RefWorks |
Amini Heidar, KhodaBande AliReza, Moghimi Sasan, Eslami Yadollah, Zarei Reza, Fakhraie Ghasem, Intraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients Iranian Journal of Ophthalmology, 2007; 19 (4) :21-27
URL http://www.irjo.org/browse.php?a_code=A-10-11-27&slc_lang=en&sid=1
Send email to the article author

Add your comments about this article
Your username or email:

Write the security code in the box >
 
Back to browse issues page Volume 19, Number 4 ( Iranian Journal of Ophthalmology 2007)
مجله چشم پزشكي ايران Iranian Journal of Ophthalmology
Static site map - Persian site map - English site map - Created in 0.078 seconds with 589 queries by AWT YEKTAWEB 2.0.6.5